Interscan Corporation - Portable Analyzer (4000 Series) with Digital Display - Hydrazine
 Search Catalog
      GO   
 All Categories    Portable Analyzer (4000 Series) with Digital Display - Hydrazine
All Categories > Gas Detection Instruments And Systems > Portable Analyzers > Portable Analyzer (4000 Series) with Digital Display - Hydrazine  > View Items 

Portable Analyzer (4000 Series) with Digital Display - Hydrazine

Check up to five results to perform an action.

Portable Analyzer Primary

larger image
4000 Series Compact Portable Analyzer Includes:
  • 3-1/2 digit LCD display
  • Appropriate sensor
  • Integral sample pump & plug-in charger
  • User-adjustable single alarm level activating audible and visual alarm
  • 0-100 mV output
  • Carrying case with shoulder strap
  • 12 inch (30.5 cm) Teflon sample probe


Search Items



    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Request InformationCompare Items   Results per Page : 
  Results 1 - 4 of 4 1 

Item #

Repeatability

Minimum Detectability

Linearity

Zero Drift

Lag Time

Range

Resolution

Special Note

4180-1999b ± 10% of full scale 10% of full scale ± 1.0% of full scale ± 10% of full scale (4 hours) Less than 1 second 0 - 1999 ppb 1 ppb Certain specification items on this model reflect performance different from most other Interscan analyzers, but are in accordance with NASA guidelines, and the extreme difficulties encountered in low-level hydrazine measurement.
4180-1000b ± 10% of full scale 10% of full scale ± 1.0% of full scale ± 10% of full scale (4 hours) Less than 1 second 0 - 1000 ppb 1 ppb Certain specification items on this model reflect performance different from most other Interscan analyzers, but are in accordance with NASA guidelines, and the extreme difficulties encountered in low-level hydrazine measurement.
4180-500b ± 10% of full scale 10% of full scale ± 1.0% of full scale ± 10% of full scale (4 hours) Less than 1 second 0 - 500 ppb 1 ppb Certain specification items on this model reflect performance different from most other Interscan analyzers, but are in accordance with NASA guidelines, and the extreme difficulties encountered in low-level hydrazine measurement.
4180-100b ± 10% of full scale 10% of full scale ± 1.0% of full scale ± 10% of full scale (4 hours) Less than 1 second 0 - 100 ppb 1 ppb Certain specification items on this model reflect performance different from most other Interscan analyzers, but are in accordance with NASA guidelines, and the extreme difficulties encountered in low-level hydrazine measurement.
  Results 1 - 4 of 4 1 

P.O. Box 2496 • Chatsworth, CA 91313-2496
TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
FAX: (818) 341-0642 • E-MAIL: info@gasdetection.com